NIRS™ DS3 oferă analiză NIR a derivatelor de carne cu o precizie excepțională. Proiectat pentru utilizare în laborator, NIRS DS3 este ideal pentru controlul rutinier.
Control the quality of meat by-products
Analyse samples from rendering production or other meat by-products with one simple analysis in less than a minute and increase your sampling frequency without extra cost. Get immediate results that enable you to adjust the production process or stop poor quality products at the gate.
Optimise your NIR management with networking software
FossManager™ networking software makes it possible to make immediate adjustments on instrument calibration and configuration remotely. Ensure consistent performance of all instruments in your network. Protect your database and calibration models with automatic back up of data.
Save time and money with innovative usability features
Easy sample preparation and intuitive user interface means that anyone can perform analysis with a minimum of training. Remote instrument monitoring allows FOSS NIR experts to troubleshoot and diagnose performance issues without interrupting operations.
Sample type
Dry samples such as meat and bone meal.
Liquid samples such as fats for petfood or energy production.
Parameters
Animal by-products: Fat, moisture, protein and ash.
Fats and oils: Free fatty acids, iodine value, peroxide value, moisture and colour.
Technology
NIR monochromator across the full spectral range from 400 to 2500 nm.
Factory standardisation ensures seamless transfer of calibrations.
| Feature | Specification |
| Dimensions (w x d x h) | 375 x 490 x 300 mm |
| Weight | 27 kg |
| Degree of protection | IP 65 |
| Measurement mode | Reflectance or transflectance (for liquids) |
| Wavelength range | 400 - 2500 nm |
| Detector | Silicon (400 - 1100 nm), Lead Sulphide, PbS (1100 - 2500 nm) |
| Optical bandwidth | 8.75 ± 0.10 nm |
| Data resolution | 0.5 nm |
| Number of data points | 4200 |
| Number of subsamples | Default: 7 for small cup; 8 for large cup |
| Self test | 12 minutes (variable) |
| Analysis time | <1 minute for 32 scans (8 subsamples, 4 scans per subsample) |
| Network connections | FossManager™ |
Installation requirements
| Voltage supply | 100-240 V AC *, frequency 50-60 Hz, Class 1, protective earth |
| Ambient temperature | 5 - 40°C |
| Storage temperature | -20 to 70°C |
| Ambient humidity | < 93% RH |
| Mechanical environment | Stationary during use |
| EMC environment | Laboratory use, industry requirements |
*Mains supply voltage fluctuations not exceeding ±10% of the rated voltage.
| Optional services | |
| Digital Services | FossAssure™ |
| Care Solutions | FossCare™, SmartCare™ |