The CombiFoss 7 seamlessly integrates MilkoScan 7 RM and Fossomatic 7 to test raw milk for up to 18 parameters, handling up to 600 samples per hour.
18 parameters from a single sample in six seconds
CombiFoss 7 has a wide range of parameters including advanced tests like ketosis screening and untargeted raw milk (adulteration) screen-ing to help your customers meet modern challenges such as dairy herd productivity, feeding efficiency and protection of the milk supply.
More results at less cost with new technology
The latest in flow system technology including a diamond cuvette technology ensures maximum uptime. The cuvette element is backed by a 10 year guarantee and you can trust in the reliability of results, whether running at 100 or 600 samples per hour.
Optimise instrument management with FOSS digital services
Ensure consistent performance of all instruments in your network and avoid downtime by making upgrades and adjustments while instruments continue to run. Protect your database and calibration models with automatic back up of data.
Sample type
Raw cow, sheep, goat and buffalo milk
Parameters
Somatic cell count, fat, protein, lactose, solids, urea, freezing point depression, Free fatty acids, casein, fatty acids profile, ketosis and others such as pH, H-index and untargeted adulteration screening
Technology
FossomaticTM 7: Flow cytometry technology. MilkoScan 7 RM: Fourier Transform InfraRed (FTIR) analysis
Approvals
SCC in compliance with ISO/IDF standards. FDA/NCIMS and MicroVal (EURL) approved
Specifications for MilkoScanTM 7 RM
Most of the calibrations are using multiple wavelengths selected freely from the entire Mid-IR spectrum in order to optimise robustness and accuracy. Compared to traditional filter calibrations, they are called full spectrum calibrations.
| Performance Carry-over for all components <1% relative | |||||
| Component | Measuring range | Performing range | Repeatability | Accuracy bulk | Accuracy single cow |
| Fat | 0-15% | 2-15% | Cv < 0.5% | Cv < 1.0% | Cv < 1.5% |
| Protein | 0-10% | 2-10% | Cv < 0.5% | Cv < 0.9% | Cv < 1.5% |
| Lactose | 0-10% | 2-10% | Cv < 0.5% | Cv < 0.9% | Cv < 1.5% |
| Solids | 0-20% | 2-20% | Cv < 0.5% | Cv < 1.0% | Cv < 1.5% |
| Urea | 10-100mg/dl | 10-100mg/dl | Sd < 1.5mg/dl | Sd < 3mg/dl | Sd < 3.5mg/dl |
| Citric acid | 0.1-0.5% | 0.1-0.5% | Sd< 0.005% | Sd < 0.01% | Sd < 0.015% |
| FPD(Screening) | 400-600 m°C | 450-550 m°C | Sd < 0.5 m°C | Sd < 4 m°C | N/A |
Novel parameters
| Fatty acids profile | see the application note no. 64 |
| Ketosis screening (BHB, acetone) | see the application note no. 64 |
| Untargeted screening raw milk (adulteration) | see the application note no. 5375 |
| Application data | |
| Analysis capacity | 100, 200, 300, 400, 500 or 600 samples per hour |
| Sample intake | 5 mL |
| Required sample temperature | 37 - 42°C |
| Performance specifications | Full spectrum calibrations |
Instrument management
Networking software: Foss Manager
Standards and Approvals
MilkoScan 7 RM is CE-labelled and complies with the following directives and regulations:
- EMC (ElectroMagnetic Compatibility) Directive 2014/30/EU
- LVD (Low Voltage) Directive 2014/35/EU
- Machinery Safety Directive 2006/42/EC
- Regulation (EC) 1272/2008 on classification, labelling and packaging of substances and mixture, CLP (EC)
- WEEE Directive 2002/96/EC
- Packaging and packaging waste Directive 94/62/EC
- REACH 1907/2006/EC
The MilkoScan 7 RM techniques comply with:
• ISO 9622 / IDF 141:2013
• AOAC official method 972.16
By using wavelengths from the entire Mid-IR spectrum for each component, calibrations are optimised in terms of robustness and/or accuracy (temperature, homogenization and humidity)
Specifications for Fossomatic 7
| Performance | |
| Measuring range | 0 – 10 mill celule/ml |
| Performance range | 0.1 – 1.5 mil |
| Repeatability | CV < 6% 100-299k SCC/ml CV < 4% 300-499k SCC/ml CV < 3% 500-1500k SCC/ml |
| Accuracy | < 10% relative mean diff. from DMSCC (Direct Microscopic Somatic Cell Count) |
| Carry-over | < 1% relativ |
| Sample types | Fossomatic 7: Cow, goat, sheep and buffalo milk |
| Application data | |
| Analysis capacity | 100, 200, 300, 400, 500 or 600 samples per hour |
| Sample intake | 2.5 ml (programmable 2.0 – 5.0 ml) |
| Required sample temperature | 37 - 42 °C (86-107.6 F) |
| Working factor | 100 |
Management Instrument
Software retea FossManager
Standards and approvals
- Fossomatic 7 is CE-labelled and complies with the following directives and regulations:
- EMC (ElectroMagnetic Compatibility) Directive 2014/30/EU
- LVD (Low Voltage) Directive 2014/35/EU
- Machinery Safety Directive 2006/42/EC
- Regulation (EC) 1272/2008 on classification, labelling and packaging of substances and mixture, CLP (EC)
- WEEE Directive 2012/19/EU
- Packaging and packaging waste Directive 94/62/EC
- REACH 1907/2006/EC
Fossomatic technology complies with:
- AOAC
- ISO 13366-2 / IDF 148-2:2006
- Laser approval (FDA), IEC 60825-1
- FDA/NCIMS and MicroVal (EURL) approved