The NIRS DA1650 Oilseed Crush Analyser allows you to take control of your oilseed crushing process with reliable measurements for whole grains, press cake, flakes, meals and oils. It is available pre-calibrated with FOSS global calibrations that are robust, low maintenance and ready to use from day one.
Just one solution for liquid and solid samples
The NIRS DA1650 Oilseed Crush Analyser helps oil crushers to gain vital process data on liquid and solid material with just one costeffective analytical unit. The intuitive touch screen interface makes it fast and easy for any user to switch between sample types.
Purpose built for your oil-crushing operation
The sealed NIRS DA1650 withstands vibration, dust or spills that can occur during regular use, ensuring accurate and robust oilseed analysis in the laboratory as well as in a harsh production environment.
Optimise your NIR management with networking software
With FossManager networking software the NIRS DA1650 is ideal for use in a group of instruments. Make immediate and remote adjustments on instrument calibration and configuration and ensure full transferability and consistent performance of all instruments in your network.
Sample type
Direct measurements of solid and liquid samples.
Parameters
Solids: Protein, moisture and oil
Liquids: Moisture, peroxide value, iodine value, FFA, phosphorus.
Technology
Diode array (DDA) based NIR reflectance and transreflectance analyser with a versatile scanning range of 1100 – 1650 nm.
| Feature | Specification |
| Dimensions (w x d x h) | 230 x 530 x 280 mm |
| Weight | 16 kg |
| Degree of protection | IP 65 (Dust and water proof) |
| Measurement mode | Reflectance or transflectance (for liquid samples) |
| Wavelength range | 1100 - 1650 nm |
| Detector | 256 pixel InGaAs diode array |
| Optical bandwidth | 10.44 ±0.5 nm |
| Spectral resolution | 0.5 nm/ data point |
| Number of data points | 1100 |
| Absorbance range | Up to 2 AU |
| Analysis time | <1 minute* |
| Wavelength accuracy | <0.5 nm |
| Wavelength precision | <0.05 nm (standard deviation) |
| Wavelength temperature stability | <0.02 nm/ °C |
*Adjustable
| Installation requirements | |
| Voltage supply | 100 - 240 V AC*, frequency 50 - 60 Hz, Class 1, protective earth |
| Ambient temperature | 5 - 40°C |
| Storage temperature | -20°C to 70°C |
| Ambient humidity | < 93% RH |
| Mechanical environment | Stationary during use |
| EMC environment | Laboratory use, Industry requirements |
*Mains supply voltage fluctuations not exceeding ±10% of the rated voltage.
| Instrument management | |
| Communication | FossManager |